Auto Reset GFCI
In-Line Cord Set
120V/15A
The in-line GFCI cord set is ideal for existing equipment
without GFCI protection. Applications include:
- Drain Snakes
- Floor Cleaners
- Signs
- Refrigeration
|
- Pumps
- Vending Machines
- Spas
|
Rainproof rated, UL listed for outdoor use. Manual reset
is required after GFCI trip and does not have to be reset with loss
of power. Allows compliance with National Electric Code (NEC
2008) Article 590.6 for "Temporary Wiring" and OSHA
regulation. Available in black only.
Auto Reset GFCI In-Line Cord Set Product Sheet
| Part Number | Features | Config | Listed |
|---|
35200-005 (2')
| - Volts/Amps: 120V/15A
- Cord Gauge: 14/3 AWG.
- NEMA 5-15 P&R
- Trip Level: 4-6 mA
|  |   |
| Trip response time for ground fault and grounded neutral trip | less than 25mS
|
| Voltage surge withstand | 3kv ringwave test and 4kv/2kA surge immunity test
|
| Radio frequency noise susceptibility | operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz
|
| Frequency | 60 Hz
|
| Endurance | 3,000 operations minimum
|
| Overload current | six times rated current
|
| Operating temperature range | -35˚C to 66˚C
|
| Insulation voltage (Hi-Pot) | 1500 VRMS - 1 Min.
|
| Power on indication | lighted indicator |